AC Motors DC Motors ELPROM-EMS
Elprom-EMS, AC MOTORS, DC MOTORS
Elprom-EMS, AC MOTORS, DC MOTORS AC MOTORS Elprom-EMS, AC MOTORS, DC MOTORS AC MOTORS Elprom-EMS, AC MOTORS, DC MOTORS
Elprom-EMS, AC MOTORS, DC MOTORS

AC motors

We produce universal as well as highly customized AC motors with rotation axes height from 56 to 100 mm that find a myriad of applications in various industries.
AC Motors applications: wood and metal working machines, hydraulic devices, air conditioning, medical and refrigeration industries and a myriad of other electric machines.
Elprom-EMS, AC MOTORS, DC MOTORS
Elprom-EMS, AC MOTORS, DC MOTORSElprom-EMS Elprom-EMS, AC MOTORS, DC MOTORS AC Motors
Elprom-EMS, AC MOTORS, DC MOTORS
AC MOTORS
Elprom-EMS, AC MOTORS, DC MOTORS
DC MOTORS
Elprom-EMS, AC MOTORS, DC MOTORS
GRINDERS
Elprom-EMS, AC MOTORS, DC MOTORS
OTHER
Elprom-EMS, AC MOTORS, DC MOTORS
Elprom-EMS, AC MOTORS, DC MOTORS
ELPROM-EMS
Elprom-EMS, AC MOTORS, DC MOTORS
CONTACT US
Elprom-EMS, AC MOTORS, DC MOTORS
News
Elprom-EMS, AC MOTORS, DC MOTORS
REQUEST FORM
Elprom-EMS, AC MOTORS, DC MOTORS
The output power is guaranteed if the electric motor is constructed in compliance with S1 operating conditions and conforms to DIN, VDE 0530 part 1 standards, 50 Hz supply system frequency, up to 40C environment temperature and not more than 1000 m altitude.

In case of deviation, the output power could be changed according to the table below:

Temperature oC 30 35 40 45 50 55 60
Output Power % 106 103 100 96 92 87 82
Height M 1000 1500 2000 2500 3000 3500 4000
Output Power % 100 97 94 90 86 82 77


The driving shaft end torque N.m. can be calculated using the following formula:
M=9.55 x P x 1000/n, where:
P-nominal power in kW and n is revolutions per minute.

Single-row ball bearings two-sides closed with low noise level are used in the electric motors. The types of bearings used are shown in the next table

Size Type Front bearing Rear bearing
56 MO.MOER 6200-2Z,C6 6200-2Z,C6
63 MO.MOER 6201-2Z,C6 6201-2Z,C6
80 MO.MOER 6204-2Z,C6 6204-2Z,C6
90 MO.MOER 6205-2Z,C6 6205-2Z,C6
100 MO 6206-2Z,C6 6206-2Z,C6


The motors are designed in compliance with the following operating standards

IEC/ISO DIN VDE NAME
IEC 34-1 DIN VDE 0530 Teil1 Rotating electrical machines. Rating and performance.
IEC 34-8 DIN VDE 0530 Teil 8 Rotating electrical machines. Part 8: Terminal markings and direction of rotation of rotating machines.
IEC 85 VDE 0530 Teil 1 Insulating materials
IEC 72   Joining and overall dimensions.
IEC 72 DIN 42 673 Teil 1 Joining dimensions and accordace of output ratings of type IM B3.
IEC 72 DIN 42 677 Teil 1 Joining dimensions and accordace of output ratings of type IM B5, IM B14.
IEC 34-5 EN 60 034 Teil 5
DIN VDE 0530 Teil 5
IEC 34-5
Rotating electrical machines. Part 5: Classification of degrees of protection by enclosures of rotating electrical machines (IP code).
IEC 34-6 DIN VDE 34-6 Rotating electrical machines. Part 6: Methods of cooling (IC code).
IEC 34-7 DIN IEC 34 Teil 7
IEC 34-7
Rotating electrical machines. Part 7: Classification of types of constructions and mounting arragements (IM code).
IEC 34-9 DIN VDE 0530 Teil 9
IEC 34-9
Rotating electrical machines. Noise. Limited values.
IEC 34-12 DIN VDE Teil 12
IEC 34-12
Rotating electrical machines. Starting characteristics of single-speed three-phase asynchronous electric motors with cage rotor for supply voltages, lower or equal to 660 V.
IEC 38 DIN IEC 38 Stadart voltages recommended by IEC.
IEC 252 DIN VDE 0560 Teil 8 Condensers; motor condensers.


The electric motors execution and assembly type can be seen here

AC Motors B3 IM1001
AC Motors V1 IM3011
AC Motors B5 IM3001
AC Motors V1 / V5 IM2011
AC Motors B3 / B5 IM2001
AC Motors V3 IM3031
AC Motors B6 IM1051
AC Motors V3 / V6 IM2031
AC Motors B7 IM1061
AC Motors V5 IM1011
AC Motors B8 IM1071
AC Motors V6 IM1031
AC Motors B14 IM3601
AC Motors V18 IM3611
AC Motors B3 / B14 IM2101
AC Motors V19 IM3611


Type MO / Three Phase
Series of induction self-ventilated

electric motors

type MO - output of the motors is from 0.06 to 4.00 kW.

Frame size from 56 up to 100 mm.

The asynchronous

electric motors

are designed for nominal supply voltage of 220/380 V, connection delta/Y and frequency of 50 Hz. At customer's request the motors can be designed with nominal supply voltage up to 400 V connection delta and up to 690 V connection Y and frequency of 60 Hz. Parameters are guaranteed with deviations of the nominal voltage no more than +/- 5%.

Prolonged operating conditions - S1 according to DIN 42950. Protection of electric and terminal devices from contact, foreign body and water penetration is, according to DIN 40050, IP 54, but can be designed with IP 55 degree of protection at customers request.

The insulation material of the primary winding is class "F" according to VDE 0530.

The above parameters are guaranteed at:
maximum environment temperature up to 40C.
maximum altitude up 1000 m.
normal climatic conditions N II.

The motors can also be in tropical (TH II) or marine (M) version, while the shape can be B3, B5 and B14 according to IEC 72, DIN 42673 and DIN 42677.

Type MOER / Single Phase
Series of induction

electric motors

with running capacitator and both starting and running capacitators type MOER - output of the motors is from 0.04 to 3.00 kW.

Frame size from 56 up to 100 mm. The motors are with cage rotors.

The induction

electric motors

are designed for nominal supply voltage of 220 V and frequency of 50 Hz. At customers request the motors can be designed with nominal supply voltage from 110 to 250 V and frequency of 60 Hz.

Parameters are guaranteed with deviations of the nominal voltage no more than +/- 5%.

Prolonged operating conditions - S1 according to DIN 42950. Protection of electric and terminal devices from contact, foreign body and water penetration is, according to DIN 40050, IP 54, but can be designed with IP 55 degree of protection at customers request.

The insulation material of the primary winding is class "F" according to VDE 0530.

The above parameters are guaranteed at:
maximum environment temperature up to 40C.
maximum altitude up 1000 m.
normal climatic conditions N II.

The motors can also be in tropical (TH II) or marine (M) version, while the shape can be B3, B5 and B14 according to IEC 72, DIN 42673 and DIN 42677.
Elprom-EMS, AC MOTORS, DC MOTORS
Elprom-EMS, AC MOTORS, DC MOTORS
Elprom-EMS, AC MOTORS, DC MOTORS ELPROM-EMS, AC motors, DC motors and Grinders Site Map Print Current Page Add To Favorites All Rights Reserved. Elprom-EMS 
 
Elprom-EMS, AC MOTORS, DC MOTORS Valid HTML 4.01 Transitional Valid CSS! Level A conformance icon, W3C-WAI Web Content Accessibility Guidelines 1.0 Elprom-EMS, AC MOTORS, DC MOTORSElprom-EMS, AC MOTORS, DC MOTORSElprom-EMS, AC MOTORS, DC MOTORSAC MotorsElprom-EMS, AC MOTORS, DC MOTORS Elprom-EMS, AC MOTORS, DC MOTORSElprom-EMS, AC MOTORS, DC MOTORSDC MotorsElprom-EMS, AC MOTORS, DC MOTORS Elprom-EMS, AC MOTORS, DC MOTORSElprom-EMS, AC MOTORS, DC MOTORSGrindersElprom-EMS, AC MOTORS, DC MOTORS Elprom-EMS, AC MOTORS, DC MOTORSElprom-EMS, AC MOTORS, DC MOTORSELPROM-EMSElprom-EMS, AC MOTORS, DC MOTORS