The output power is guaranteed if the electric motor is constructed in compliance with S1 operating conditions and conforms to DIN, VDE 0530 part 1 standards, 50 Hz supply system frequency, up to 40C environment temperature and not more than 1000 m
altitude.
In case of deviation, the output power could be changed according to the table below:
Height |
M |
1000 |
1500 |
2000 |
2500 |
3000 |
3500 |
4000 |
Output Power |
% |
100 |
97 |
94 |
90 |
86 |
82 |
77 |
|
The driving shaft end torque N.m. can be calculated using the following formula:
M=9.55 x P x 1000/n, where:
P-nominal power in kW and n is revolutions per minute.
Single-row ball bearings two-sides closed with low noise level are used in the electric motors. The types of bearings used are shown in the next table
56 |
MO.MOER |
6200-2Z,C6 |
6200-2Z,C6 |
63 |
MO.MOER |
6201-2Z,C6 |
6201-2Z,C6 |
80 |
MO.MOER |
6204-2Z,C6 |
6204-2Z,C6 |
90 |
MO.MOER |
6205-2Z,C6 |
6205-2Z,C6 |
100 |
MO |
6206-2Z,C6 |
6206-2Z,C6 |
|
The motors are designed in compliance with the following operating standards
IEC 34-1 |
DIN VDE 0530 Teil1 |
Rotating electrical machines. Rating and performance. |
IEC 34-8 |
DIN VDE 0530 Teil 8 |
Rotating electrical machines. Part 8: Terminal markings and direction of rotation of rotating machines. |
IEC 85 |
VDE 0530 Teil 1 |
Insulating materials |
IEC 72 |
|
Joining and overall dimensions. |
IEC 72 |
DIN 42 673 Teil 1 |
Joining dimensions and accordace of output ratings of type IM B3. |
IEC 72 |
DIN 42 677 Teil 1 |
Joining dimensions and accordace of output ratings of type IM B5, IM B14. |
IEC 34-5 |
EN 60 034 Teil 5 DIN VDE 0530 Teil 5 IEC 34-5 |
Rotating electrical machines. Part 5: Classification of degrees of protection by enclosures of rotating electrical machines (IP code). |
IEC 34-6 |
DIN VDE 34-6 |
Rotating electrical machines. Part 6: Methods of cooling (IC code). |
IEC 34-7 |
DIN IEC 34 Teil 7 IEC 34-7 |
Rotating electrical machines. Part 7: Classification of types of constructions and mounting arragements (IM code). |
IEC 34-9 |
DIN VDE 0530 Teil 9 IEC 34-9 |
Rotating electrical machines. Noise. Limited values. |
IEC 34-12 |
DIN VDE Teil 12 IEC 34-12 |
Rotating electrical machines. Starting characteristics of single-speed three-phase asynchronous electric motors with cage
rotor for supply voltages, lower or equal to 660 V. |
IEC 38 |
DIN IEC 38 |
Stadart voltages recommended by IEC. |
IEC 252 |
DIN VDE 0560 Teil 8 |
Condensers; motor condensers. |
|
The electric motors execution and assembly type can be seen here
|
B3 |
IM1001 |
|
|
|
V1 |
IM3011 |
|
|
B5 |
IM3001 |
|
|
|
V1 / V5 |
IM2011 |
|
|
B3 / B5 |
IM2001 |
|
|
|
V3 |
IM3031 |
|
|
B6 |
IM1051 |
|
|
|
V3 / V6 |
IM2031 |
|
|
B7 |
IM1061 |
|
|
|
V5 |
IM1011 |
|
|
B8 |
IM1071 |
|
|
|
V6 |
IM1031 |
|
|
B14 |
IM3601 |
|
|
|
V18 |
IM3611 |
|
|
B3 / B14 |
IM2101 |
|
|
|
V19 |
IM3611 |
|
Type MO / Three Phase Series of induction self-ventilated type MO - output of the motors is from 0.06 to 4.00 kW.
Frame size from 56 up to 100 mm.
The asynchronous are designed for nominal supply voltage of 220/380 V, connection delta/Y and frequency of 50 Hz. At customer's request the motors can be designed with nominal supply voltage up to 400 V connection delta and up to 690 V connection Y and frequency of 60 Hz. Parameters are guaranteed with deviations of the nominal voltage no more than +/- 5%.
Prolonged operating conditions - S1 according to DIN 42950. Protection of electric and terminal devices from contact, foreign body and water penetration is, according to DIN 40050, IP 54, but can be designed with IP 55 degree of protection at customers request.
The insulation material of the primary winding is class "F" according to VDE 0530.
The above parameters are guaranteed at:
maximum environment temperature up to 40C.
maximum altitude up 1000 m.
normal climatic conditions N II.
The motors can also be in tropical (TH II) or marine (M) version, while the shape can be B3, B5 and B14 according to IEC 72, DIN 42673 and DIN 42677.
Type MOER / Single Phase Series of induction with running capacitator and both starting and running capacitators type MOER - output of the motors is from 0.04 to 3.00 kW.
Frame size from 56 up to 100 mm. The motors are with cage rotors.
The induction are designed for nominal supply voltage of 220 V and frequency of 50 Hz. At customers request the motors can be designed with nominal supply voltage from 110 to 250 V and frequency of 60 Hz.
Parameters are guaranteed with deviations of the nominal voltage no more than +/- 5%.
Prolonged operating conditions - S1 according to DIN 42950. Protection of electric and terminal devices from contact, foreign body and water penetration is, according to DIN 40050, IP 54, but can be designed with IP 55 degree of protection at customers request.
The insulation material of the primary winding is class "F" according to VDE 0530.
The above parameters are guaranteed at:
maximum environment temperature up to 40C.
maximum altitude up 1000 m.
normal climatic conditions N II.
The motors can also be in tropical (TH II) or marine (M) version, while the shape can be B3, B5 and B14 according to IEC 72, DIN 42673 and DIN 42677.
|
|
|